Panasonic FP? Positioning Unit RTEX Technical Manual page 140

Automation controls
Table of Contents

Advertisement

Operation at limit input
Condition
When Position control is
executed
During position control
8-38
Direction
Limit status
Limit input(+):ON
Forward
Limit input (-):ON
Limit input(+):ON
Reverse
Limit input (-):ON
Forward
Limit input(+):ON
Reverse
Limit input (-):ON
Operation
Not executable, Error occurs.
Not executable, Error occurs.
Not executable, Error occurs.
Not executable, Error occurs.
Deceleration stop, Error occurs.
Deceleration stop, Error occurs.