Figure 12-23 Save Calibration Result screen
• Replace - Only overwrites the current channel and power values with the new channel power values the
Interactive Calibration has calculated.
• Write - Writes the new channel and power values to the radios under their respective device configurations.
• Discard - Discards the results of the Interactive Calibration without applying them to their respective devices.
• Commit - Commits the Smart RF module Interactive Calibration results to their respective access point radios.
5. Select the
Run Calibration
option to initiate a calibration. New channel and power values are applied to radios,
they are not written to the running-configuration. These values are dynamic and may keep changing during the
course of the run-time monitoring and calibration the Smart RF module keeps performing to continually maintain
good coverage. Unlike an Interactive Calibration, the Smart RF screen is not populated with the changes needed
on access point radios to remedy a detected coverage hole. Expand the screen to display the Event Monitor to
track the progress of the calibration.
The calibration process can be stopped by selecting the
Stop Calibration
button.