5 - 154 WiNG 5 Access Point System Reference Guide
10. Set the following parameters to add or modify MINT VLAN configuration:
VLAN
Routing Level
Link Cost
Hello Packet Interval
Adjacency Hold Time
11. Select
OK
configuration.
Figure 5-86 Advanced Profile MINT screen - Add/edit VLAN
If adding a new VLAN, define a VLAN ID between 1 - 4,094 used by peers
for interoperation when supporting the MINT protocol.
If adding a new VLAN, use the spinner control to define a routing level of
either 1 or 2.
Use the spinner control to define a link cost between 1 - 10,000. The default
value is 100.
Set an interval in either Seconds (1 - 120) or Minutes (1 - 2) for the
transmission of hello packets. The default interval is 4 seconds.
Set a hold time interval in either Seconds (2 - 600) or Minutes (1 - 10) for
the transmission of hello packets. The default interval is 13 seconds.
to save the updates to the MINT Protocol configuration. Select
Reset
to revert to the last saved