Motorola WiNG 5 System Reference Manual page 459

Table of Contents

Advertisement

Reconnect Attempts
Reconnect Interval
Retry Count
Retry Time Out
Rx Window Size
Tx Window Size
6. Select
OK
to save the updates to the L2TP V3 Policy Details. Select
Use the spinner control to set a value (from 0 - 250) representing the
maximum number of reconnection attempts initiated to reestablish the
tunnel.The default interval is 5.
Define an interval in either Seconds (1 - 3,600), Minutes (1 -60) or Hours (1)
between two successive reconnection attempts. The default setting is 2
minutes.
Use the spinner control to define how many retransmission attempts are
made before determining a target tunnel peer is not reachable. The
available range is from 1 - 10, with a default value of 5.
Use the spinner control to define the interval (in seconds) before initiating
a retransmission of a L2TP V3 signaling message. The available range is
from 1 - 250, with a default value of 5.
Specify the number of packets that can be received without sending an
acknowledgement.The available range is from 1 - 15, with a default setting
of 10.
Specify the number of packets that can be transmitted without receiving
an acknowledgement. The available range is from 1 - 15, with a default
setting of 10.