5 - 258 WiNG 5 Access Point System Reference Guide
Hold Time
Timer
Inventory
Management
Discovery
Extended Power via
MDI Discovery
7. Select the
last saved configuration.
Use the spinner control to set the hold time (in seconds) for transmitted LLDP
PDUs. Set a value in the range of 10 - 1,800. The default hold time is 180.
Set the interval used to transmit LLDP PDUs. Define an interval from 5 - 900
seconds. The default setting is 60 seconds.
Select this option to include LLPD-MED inventory management discovery
TLV in LLDP PDUs. This Setting is enabled by default.
Select this option to include LLPD-MED extended power via MDI discovery
TLV in LLDP PDUs. This Setting is disabled by default
OK
button to save the changes and overrides to the LLDP configuration. Select
Reset
to revert to the

Hide quick links: