Network Interfaces for EX4300 Switches
Sample Output
show interfaces diagnostics optics xe-0/1/0 (SFP+ Transceiver)
270
Laser bias current low warning threshold
Laser output power high alarm threshold
Laser output power low alarm threshold
Laser output power high warning threshold :
Laser output power low warning threshold
Module temperature high alarm threshold
Module temperature low alarm threshold
Module temperature high warning threshold :
Module temperature low warning threshold
Module voltage high alarm threshold
Module voltage low alarm threshold
Module voltage high warning threshold
Module voltage low warning threshold
Laser rx power high alarm threshold
Laser rx power low alarm threshold
Laser rx power high warning threshold
Laser rx power low warning threshold
user@switch> show interfaces diagnostics optics xe-0/1/0
Physical interface: xe-0/1/0
Laser bias current
Laser output power
Module temperature
Module voltage
Receiver signal average optical power
Laser bias current high alarm
Laser bias current low alarm
Laser bias current high warning
Laser bias current low warning
Laser output power high alarm
Laser output power low alarm
Laser output power high warning
Laser output power low warning
Module temperature high alarm
Module temperature low alarm
Module temperature high warning
Module temperature low warning
Module voltage high alarm
Module voltage low alarm
Module voltage high warning
Module voltage low warning
Laser rx power high alarm
Laser rx power low alarm
Laser rx power high warning
Laser rx power low warning
Laser bias current high alarm threshold
Laser bias current low alarm threshold
Laser bias current high warning threshold :
Laser bias current low warning threshold
Laser output power high alarm threshold
Laser output power low alarm threshold
Laser output power high warning threshold :
Laser output power low warning threshold
Module temperature high alarm threshold
Module temperature low alarm threshold
Module temperature high warning threshold :
Module temperature low warning threshold
:
2.000 mA
:
0.6300 mW / -2.01 dBm
:
0.0660 mW / -11.80 dBm
0.6300 mW / -2.01 dBm
:
0.0780 mW / -11.08 dBm
:
109 degrees C / 228 degrees F
:
-29 degrees C / -20 degrees F
103 degrees C / 217 degrees F
:
-13 degrees C / 9 degrees F
:
3.900 V
:
2.700 V
:
3.700 V
:
2.900 V
:
1.2589 mW / 1.00 dBm
:
0.0100 mW / -20.00 dBm
:
0.7939 mW / -1.00 dBm
:
0.0157 mW / -18.04 dBm
:
4.968 mA
:
0.4940 mW / -3.06 dBm
:
27 degrees C / 81 degrees F
:
3.2310 V
:
0.0000
:
Off
:
Off
:
Off
:
Off
:
Off
:
Off
:
Off
:
Off
:
Off
:
Off
:
Off
:
Off
:
Off
:
Off
:
Off
:
Off
:
Off
:
On
:
Off
:
On
:
10.500 mA
:
2.000 mA
9.000 mA
:
2.500 mA
:
1.4120 mW / 1.50 dBm
:
0.0740 mW / -11.31 dBm
0.7070 mW / -1.51 dBm
:
0.1860 mW / -7.30 dBm
:
75 degrees C / 167 degrees F
:
-5 degrees C / 23 degrees F
70 degrees C / 158 degrees F
:
0 degrees C / 32 degrees F