20.1.2 Component: AlarmManager#0

Alarm:
OID:
Default Severity
Event Type:
Probable Cause:
Alarm Text:
Status Changes:
Condition:
Alarm status:
Condition:
Alarm status:
Note:
Corrective Action:

20.1.3 Component: EthernetLink#0

This trap is related to the Ethernet Link Module (the #0 numbering does not apply on the
physical Ethernet link).
Version 4.6

Table 20-3: acActiveAlarmTableOverflow Alarm Trap

acActiveAlarmTableOverflow
1.3.6.1.4.15003.9.10.1.21.2.0.12
Major
processingErrorAlarm
resourceAtOrNearingCapacity (43)
Active alarm table overflow
Too many alarms to fit in the active alarm table
Major
After raise
Status stays major until reboot. A clear trap is not sent.
The status stays major until reboot as it denotes a possible loss of
information until the next reboot. If an alarm was raised when the table
was full, it is possible that the alarm is active, but does not appear in the
active alarm table.
Some alarm information may have been lost, but the ability of the device
to perform its basic operations has not been impacted. A reboot is the
only way to completely clear a problem with the active alarm table.
Contact your first-level group.