Table 20-4: acBoardEthernetLinkAlarm Alarm Trap
Alarm:
OID:
Default Severity
Event Type:
Probable Cause:
Alarm Text:
Status Changes:
Condition:
Alarm status:
<text> value:
Condition:
Alarm status:
<text> value:
Condition:
Alarm status:
Corrective Action:
20.2
Log Traps (Notifications)
This section details traps that are not alarms. These traps are sent out with the severity
varbind value of "indeterminate". These traps do not clear, they do not appear in the alarm
history or active tables. One log trap that does send out clear is
acPerformanceMonitoringThresholdCrossing.
User's Manual
acBoardEthernetLinkAlarm
1.3.6.1.4.1.5003.9.10.1.21.2.0.10
Critical
equipmentAlarm
underlyingResourceUnavailable (56)
Ethernet link alarm: <text>
Fault on single interface
Major
Redundant link is down
Fault on both interfaces
critical
No Ethernet link
Both interfaces are operational
cleared
Ensure that both Ethernet cables are plugged into the back of the system.
Inspect the system's Ethernet link lights to determine which interface is
failing. Reconnect the cable or fix the network problem