8.1.5.1

SNMP Community Names

By default, the board uses a single, read-only community string of "public" and a single
read-write community string of "private".
One can configure up to 5 read-only community strings and up to 5 read-write community
strings, and a single trap community string is supported:
8.1.5.1.1 Configuration of Community Strings via the ini File
SNMPREADONLYCOMMUNITYSTRING_<x> = '#######'
SNMPREADWRITECOMMUNITYSTRING_<x> = '#######'
Where <x> is a number between 0 and 4, inclusive. Note that the '#' character represents
any alphanumeric character. The maximum length of the string is 20 characters.
8.1.5.1.2 Configuration of Community Strings via SNMP
To configure read-only and read-write community strings, the EM must use the
srCommunityMIB. To configure the trap community string, the EM must also use the
snmpVacmMIB and the snmpTargetMIB.
To add a read-only community string, v2user, take this step:
Add a new row to the srCommunityTable with CommunityName v2user and
GroupName ReadGroup.
To delete the read-only community string, v2user, take these 2
steps:
If v2user is being used as the trap community string, follow the procedure for changing
1.
the trap community string. (See below.)
Delete the srCommunityTable row with CommunityName v2user.
2.
To add a read-write community string, v2admin, take this step:
Add a new row to the srCommunityTable with CommunityName of v2admin and
GroupName ReadWriteGroup.
To delete the read-write community string, v2admin, take these 2
steps:
If v2admin is being used as the trap community string, follow the procedure for
1.
changing the trap community string. (See below.)
Delete the srCommunityTable row with a CommunityName of v2admin and
2.
GroupName of ReadWriteGroup.
To change the only read-write community string from v2admin to
v2mgr, take these 4 steps:
Follow the procedure above to add a read-write community string to a row for v2mgr.
1.