Reset Button; Figure 8-50: Reset Screen - AudioCodes Mediant 1000 User Manual

Voip mediant digital media gateways megaco, tpncp
Hide thumbs Also See for Mediant 1000:
Table of Contents

Advertisement

User's Manual
8.10

Reset Button

The Reset link in the main menu on the left allows the user to initiate a device reset
following which the device utilizes the new configuration stored in the non-volatile (flash)
memory.
To use the Reset Button screen, take these 4 steps:
From the main menu list on the left, click on the Reset button. The Reset screen is
1.
displayed.
Select either of the following Burn options:
2.
Burn - (Default setting) burns the current configuration to non-volatile (flash) prior
to reset
Don't Burn - Resets the device without first burning the current configuration to
non-volatile (discards all modifications to the configuration that were not saved to
non-volatile memory)
Select either of the following Graceful Shutdown options:
3.
Yes - a timer configuration input field appears - Reset starts only after the timer
expires or no more active traffic exists (the earliest thereof)
No - immediate reset, any existing traffic is terminated at once
Click the Restart Button. If Graceful shutdown was selected, the reset is delayed and
4.
a screen displaying the number of remaining calls and the timer count is displayed. If
Graceful shutdown was not selected the reset starts immediately.
When the reset initiates, If the Burn option is selected, all of the changes made to the
configuration are saved to the non-volatile memory of the device. If the Don't Burn
option is selected, all of the changes made to the configuration are discarded. The
device is shut down and re-activated. A message about the waiting period is
displayed. The screen is refreshed.
Version 4.6

Figure 8-50: Reset Screen

185
8. Mediant 1000 Management
August 2005

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents