AudioCodes Mediant 1000 User Manual page 69

Voip mediant digital media gateways megaco, tpncp
Hide thumbs Also See for Mediant 1000:
Table of Contents

Advertisement

User's Manual
Ringback Tone
4.
Busy Tone
5.
Congestion Tone
6.
N/A
7.
Warning Tone
8.
Reorder Tone
9.
Confirmation Tone
10.
Call Waiting Tone
11.
For a full tone indices list, refer to enum definition in the "VoPLib API Reference Manual",
Document #: LTRT-840xx.
Tone Modulation Type – The tone may be either Amplitude Modulated (1) or regular
(0).
Tone Form – The format of the tone may be one of the following indices:
Continuous
Cadence
Burst
Low Freq [Hz] - Frequency in Hertz of the lower tone component for a dual frequency
tone, or the frequency of the tone for a single tone. This parameter is relevant only in
case the tone is not Amplitude Modulated.
High Freq [Hz] - Frequency in Hertz of the higher tone component for of a dual
frequency tone, or zero (0) for a single tone. This parameter is relevant only in case
the tone is not modulated.
Low Freq Level [-dBm] - Generation level 0 dBm to -31 dBm. This parameter is
relevant only in case the tone is not Amplitude Modulated.
High Freq Level [-dBm] - Generation level. 0 to -31 dBm. The value should be zero
(0) for a single tone. This parameter is relevant only in case the tone is not Amplitude
Modulated.
First Signal On Time [10 msec] - "Signal On" period (in 10 msec units) for the first
cadence ON-OFF cycle, for cadence tone. When a tone is configured to be
continuous, this parameter defines the tone On event detection time. When a tone is
configured to be burst tone, it defines the tone's duration.
First Signal Off Time [10 msec] - "Signal Off" period (in 10 msec units) for the first
cadence ON-OFF cycle, for cadence tone. In case of burst tone, this parameter
defines the off time required after burst tone ended until the tone detection is reported.
For a continuous tone, this parameter is ignored.
Second Signal On Time [10 msec] - "Signal On" period (in 10 msec units) for the
second cadence ON-OFF cycle. This may be omitted if there is no second cadence.
Second Signal Off Time [10 msec] - "Signal Off" period (in 10 msec units) for the
second cadence ON-OFF cycle. This may be omitted if there is no second cadence.
Third Signal On Time [10 msec] - "Signal On" period (in 10 msec units) for the third
cadence ON-OFF cycle. This may be omitted if there is no third cadence.
Third Signal Off Time [10 msec] - "Signal Off" period (in 10 msec units) for the third
cadence ON-OFF cycle. This may be omitted if there is no third cadence.
Version 4.6