Download Print this page

Subaru 2009 IMPREZA Service Manual page 1510

Hide thumbs Also See for 2009 IMPREZA:

Advertisement

Diagnostic Procedure with Diagnostic Trouble Code (DTC)
Step
1
CHECK HARNESS BETWEEN ECM AND
TUMBLE GENERATOR VALVE ASSEMBLY
RH CONNECTOR.
1) Turn the ignition switch to OFF.
2) Disconnect the connectors from the ECM
and tumble generator valve assembly RH.
3) Measure the resistance of harness between
ECM and tumble generator valve assembly RH.
Connector & terminal
(B137) No. 22 — (E55) No. 5:
(B137) No. 23 — (E55) No. 4:
2
CHECK HARNESS BETWEEN ECM AND
TUMBLE GENERATOR VALVE ASSEMBLY
RH CONNECTOR.
Measure the resistance between ECM and
chassis ground.
Connector & terminal
(B137) No. 22 — Chassis ground:
(B137) No. 23 — Chassis ground:
3
CHECK POOR CONTACT.
Check for poor contact of tumble generator
valve assembly RH connector.
Check
Is the resistance less than 1 ? Go to step 2.
Is the resistance 1 M or
more?
Is there poor contact of the tum-
ble generator valve assembly
RH connector?
EN(H4DOTC)(diag)-289
ENGINE (DIAGNOSTICS)
Yes
No
Repair the harness
and connector.
NOTE:
In this case, repair
the following item:
• Open circuit in
harness between
ECM and tumble
generator
assembly RH con-
nector
• Poor contact of
coupling connector
Go to step 3.
Repair the short
circuit to ground in
harness between
ECM and tumble
generator valve
assembly RH con-
nector.
Repair the poor
Replace the tum-
contact of tumble
ble generator valve
generator valve
assembly RH.
assembly RH con-
<Ref. to
nector.
FU(H4DOTC)-44,
Tumble Generator
Valve Assembly.>
valve

Advertisement

loading