Download Print this page

Subaru 2009 IMPREZA Service Manual page 1058

Hide thumbs Also See for 2009 IMPREZA:

Advertisement

3) Remove the boost hose (B) from the waste gate
actuator (A) of the turbocharger, and connect the
Mighty Vac to the waste gate actuator (A).
(D)
(A) Waste gate actuator
(B) Boost hose
(C) Control rod
(D) Control rod stroke
4) Pressurize slowly with the Mighty Vac, and mea-
sure the pressure when the control rod stroke (D)
becomes 2 mm (0.08 in). If it is not within the stan-
dard, replace the turbocharger assembly.
CAUTION:
Do not pressurize over 89.9 kPa (0.92 kgf/cm
13.0 psi) to prevent damaging the waste gate
actuator.
Operating pressure
(Control rod stroke 2 mm (0.08 in)):
Standard
74.7 — 80.8 kPa
(0.76 — 0.82 kgf/cm
5) After inspection, install the related parts in the
reverse order of removal.
Tightening torque:
7.5 N·m (0.8 kgf-m, 5.5 ft-lb)
2. OIL PIPE AND WATER PIPE
• Check that there are no oil leakage or water leak-
age from the pipe attachment section.
• Check for cracks or loose connections.
Turbocharger
(A)
IN-02570
2
, 10.8 — 11.7 psi)
EX-02431
IN(H4DOTC)-19
2
,
INTAKE (INDUCTION)