B: INSPECTION
OPERATING CONDITION:
Vehicle speed
During acceleration: 19 km/h
(12 MPH) or less
During deceleration: 10 km/h
(6 MPH) or less
During acceleration: 20 — 69 km/h
(12 — 43 MPH)
During deceleration: 11 — 64 km/h
(7 — 40 MPH)
During acceleration: 70 — 105 km/h
(43 — 65 MPH)
During deceleration: 65 — 103 km/h
(40 — 64 MPH)
During acceleration: 106 km/h
(66 MPH) or more
During deceleration: 104 km/h
(65 MPH) or more
DIAGNOSIS:
Radiator main fan and radiator sub fans do not rotate under the above operating conditions.
Step
1
CHECK OPERATION OF RADIATOR FAN.
1) Connect the delivery (test) mode connector.
2) Turn the ignition switch to ON.
3) Using the Subaru Select Monitor, check the
forced operation of the radiator fan relay.
NOTE:
• When performing a forced operation radiator
fan relay check using the Subaru Select Moni-
tor, the radiator main fan and radiator sub fan
will repeat low speed revolution
revolution
OFF in this order.
• Subaru Select Monitor
Refer to "Compulsory Valve Operation Check
Mode" for detailed procedures. <Ref. to
EN(H4DOTC)(diag)-55, Compulsory Valve Op-
eration Check Mode.>
Radiator Fan System
Increase: 94°C
A/C compressor
(201°F) or less
load
Decrease: 91°C
(196°F) or less
Radiator fan operation Radiator fan operation Radiator fan operation
OFF
OFF
Low
Low-Speed
High
High-Speed
OFF
OFF
Low
High-Speed
High
High-Speed
OFF
OFF
Low
High-Speed
High
High-Speed
OFF
OFF
Low
High-Speed
High
High-Speed
Do the radiator main fans and
radiator sub fans rotate at low
speed?
high speed
CO(H4DOTC)-9
Engine coolant temperature
Increase: 95 — 96°C
(203 — 205°F)
Decrease: 92 — 94°C
(198 — 201°F)
Low-Speed
Low-Speed
High-Speed
Low-Speed
High-Speed
High-Speed
Low-Speed
High-Speed
High-Speed
High-Speed
High-Speed
High-Speed
Check
Yes
Go to step 2.
COOLING
Increase: 97°C
(207°F) or more
Decrease: 95°C
(203°F) or more
High-Speed
High-Speed
High-Speed
High-Speed
High-Speed
High-Speed
High-Speed
High-Speed
High-Speed
High-Speed
High-Speed
High-Speed
No
Go to step 3.

Advertisement