PARAMETER DEFINITIONS - A500/F500 SERIES

7.2.2 Parameter clear

Parameter clear can be performed from the master.
PNU
P2.1 User clear value setting
P2.2 Parameter clear
P2.3 Parameter all clear
P2.4 Parameter user clear
P2.5 Parameter clear (*1)
P2.6 Parameter all clear (*1)
P2.7 Parameter user clear (*1)
P2.8 Error history clear
*1 Communication parameters (Pr. 117 to Pr. 124, Pr. 331 to Pr. 342) are not
cleared.

7.2.3 Operation mode read/write

Read/write of the operation mode can be performed from the master.
PNU
P3
Operation mode read/write

7.2.4 Set frequency read

The frequency set to the inverter can be read from the master.
PNU
P4.1 Set frequency (RAM) read
P4.2 Set frequency (E

7.2.5 Terminal input read

The setting of the No. 2 terminal can be read.
PNU
P5
No. 2 terminal input value read

7.2.6 Inverter reset

The inverter can be reset from the master.
PNU
Item
P6
Inverter reset
• The inverter maintains the resetting status while reset is requested.
• When Pr. 75 ≠ "0, 2, 14, 16", reset is enabled only during an inverter
error.
Item
Item
Item
2
PROM) read
Item
The inverter is reset after the data
was written to the master.
50
Data Definition
Set parameter number
965AH
99AAH
5A55H
5A96H
AA99H
555AH
0000H
Data Definition
NET
:14H
External :10H
Data Definition
Set frequency (RAM) is
read.
Set frequency
2
(E
PROM) is read.
Data Definition
No. 2 terminal input
value (%) is read.
Data Definition
Data Type
AUs16
AUs16
AUs16
AUs16
AUs16
AUs16
AUs16
AUs16
Data Type
Us16
Data Type
AUs16
AUs16
Data Type
Us16
Data Type
Us16