REP 19.0 Paper Path Frame
Workcentre PE220
Parts list on
PL 6.0
WARNING
Switch off the electricity to the machine. Dis-
connect the power cord from the customer
supply while performing tasks that do not
need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
1. Remove the scan assembly,
2. Remove the middle cover,
3. Remove the fuser,
4. Remove the engine shield,
5. Remove 4 screws securing the paper path
frame and remove it in the direction of the
arrow, Figure 1.
Figure 1
Phaser 3200MFP / Workcentre PE220
REP
8.
REP
12.
REP
16.0.
REP
17.
6. Remove the transfer roller from the frame,
Figure 2.
7. Remove the screw securing the solenoid-
MP and remove it, Figure 3.
Replacement
Replacement is the reverse of the removal
procedure.
04/07
Repairs/Adjustments
Figure 2
Figure 3
4-37