To change the Backup Hello interval, enter a command such as the following at the configuration
level for the VRID.
BigIron RX(config-vlan-200-vrid-1)# backup-hello-interval 180
Syntax: [no] backup-hello-interval <units>
The <units> parameter specifies the message interval and can be from 60 – 3600 units (1 unit =
100 milliseconds). The default is 60 units (6000 milliseconds or 6 seconds).
NOTE
If you change the timer scale, the change affects the actual number of seconds.

Changing the hold-down interval

The hold-down interval prevents Layer 2 loops from occurring during failover, by delaying the new
Master from forwarding traffic long enough to ensure that the failed Master is really unavailable.
To change the Hold-down interval, enter a command such as the following at the configuration level
for the VRID.
BigIron RX(config-vlan-200-vrid-1)# hold-down-interval 4
Syntax: [no] hold-down-interval <units>
The <units> parameter specifies the hold-down interval and can be from 2 – 84 units (1 unit = 100
milliseconds). The default is 3 (3 units = 300 milliseconds)
NOTE
If you change the timer scale, the change affects the actual number of seconds.

Changing the default track priority

When you configure a VRID to track the link state of other interfaces, if one of the tracked interface
goes down, the software changes the VSRP priority of the VRID interface.
The software reduces the VRID priority by the amount of the priority of the tracked interface that
went down. For example, if the VSRP interface's priority is 100 and a tracked interface with track
priority 60 goes down, the software changes the VSRP interface's priority to 40. If another tracked
interface goes down, the software reduces the VRID's priority again, by the amount of the tracked
interface's track priority.
The default track priority for all track ports is 1. You can change the default track priority or
override the default for an individual track port:
To change the track priority, enter a command such as the following at the configuration level for
the VRID.
BigIron RX(config-vlan-200-vrid-1)# backup track-priority 2
Syntax: [no] backup [priority <value>] [track-priority <value>]
BigIron RX Series Configuration Guide
53-1001810-01
To change the default track priority, use the backup track-priority command, described below.
To override the default track priority for a specific track port, use the track-port command.
Refer to
"Specifying a track port"
Configuring optional VSRP parameters
on page 426.