BiDirectional Forwarding Detection (BFD)

In this chapter

BigIron RX provides support for Bidirectional Forwarding Detection (BFD) in Version 02.6.00 of the
Multi-Service IronWare software. BFD defines a method of rapid detection of the failure of a
forwarding path by checking that the next hop router is alive. Without BFD enabled, it can take from
3 to 30 seconds to detect that a neighboring router is not operational causing packet loss due to
incorrect routing information at a level unacceptable for real-time applications such as VOIP and
video over IP. Using BFD, you can detect a forwarding path failure in 300 milliseconds or less
depending on your configuration.
A BFD session is automatically established when a neighbor is discovered for a protocol provided
that BFD is enabled on the interface on which the neighbor is discovered and BFD is also enabled
for the protocol (by interface or globally). Once a session is set-up, each router transmits control
messages at a high rate of speed that is negotiated by the routers during the session setup. To
provide a detection time of 150 milliseconds, it is necessary to process 20 messages per second of
about 70 to 100 bytes each per each session. A similar number of messages also need to be
transmitted out per each session. Once a session is set-up, that same message is continuously
transmitted at the negotiated rate and a check is made that the expected control message is
received at the agreed frequency from the neighbor. If the agreed upon messages are not received
from the neighbor within a short period of time, the neighbor is considered to be down. The
maximum number of sessions supported on an interface module (LP) is 20 while the maximum per
system is 100.
NOTE
BFD session establishment on an interface does not start until 90 seconds after the interface
comes up. The reason for this delay is to ensure that the link is not effected by unstable link
conditions which could cause BFD to flap. This delay time is not user configurable.
The BFD Control Message is an UDP message with destination port 3784.
NOTE
BFD version 0 is not supported in this implementation and BFD version 1 is not compatible with BFD
version 0.
NOTE
BFD supports multi-slot trunks in cases where all BFD packet are transmitted only on a single path
which does not change unless the trunk active membership changes. BFD is not be supported on
multi-slot trunks where per-packet switching is used such that the path taken by the BFD packets
will vary per packet.
BigIron RX Series Configuration Guide
53-1001810-01
Configuring BFD parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 918
Displaying Bidirectional Forwarding Detection information . . . . . . . . . . . . 919
Configuring BFD for the specified protocol . . . . . . . . . . . . . . . . . . . . . . . . . 923
Chapter
30
917

Advertisement

Table of Contents
loading

This manual is also suitable for:

Brocade dcx-4sBrocade dcx

Table of Contents