Dell PowerConnect B-RX Configuration Manual page 429

Bigiron rx series configuration guide v02.7.02
Hide thumbs Also See for PowerConnect B-RX:
Table of Contents

Advertisement

FIGURE 46
At this point, the handshake mechanism is complete between Switch 100, the root bridge, and
Switch 200.
Switch 200 updates the information on the Switch 200's Designated ports (Port2 and Port3) and
identifies the new root bridge. The Designated ports send RST BPDUs, containing proposal flags, to
their downstream bridges, without waiting for the hello timers to expire on them. This process
starts the handshake with the downstream bridges.
For example, Port2/Switch 200 sends an RST BPDU to Port2/Switch 300 that contains a proposal
flag. Port2/Switch 300 asserts a proposed signal. Ports in Switch 300 then set sync signals on the
ports to synchronize and negotiate their roles and states. Then the ports assert a synced signal and
when the Root port in Switch 300 asserts it is synced signal, it sends an RST BPDU to Switch 200
with an agreed flag.
This handshake is repeated between Switch 200 and Switch 400 until all Designated and Root
ports are in forwarding states.
BigIron RX Series Configuration Guide
53-1001810-01
Agreed – The Root port sends back an RST BPDU containing an agreed flag to its peer
Designated port and moves into the forwarding state. When the peer Designated port receives
the RST BPDU, it rapidly transitions into a forwarding state.
Agree stage
Port2
Switch 300
Port1
Designated port
Forwarding
RST BPDU
Port1
sent with
Root port
an Agreed
Synced
flag
Forwarding
BigIron
Port2
Synced
Discarding
Indicates a signal
State machines
Switch 100
Root Bridge
Switch 200
Port3
Synced
Discarding
Port3
Switch 400
13
357