Configuration Examples - Dell PowerConnect B-RX Configuration Manual

Bigiron rx series configuration guide v02.7.02
Hide thumbs Also See for PowerConnect B-RX:
Table of Contents

Advertisement

This command displays the following information.
TABLE 74
This field...
Port
Method

Configuration examples

The examples use two common configurations:
Tagged port using default VLAN 1 as its port native VLAN
In
Figure
and 4 as tagged VLANs.
FIGURE 32
To implement this configuration, enter the following commands on the RX.
BigIron RX(config)# vlan-group 1 vlan 2 to 4
BigIron RX(config-vlan-group-1)# tagged ethernet 1/1
BigIron RX(config-vlan-group-1)# exit
BigIron RX(config)# interface ethernet 1/1
BigIron RX(config-if-e10000-1/1)# pvst-mode
These commands configure a VLAN group containing VLANs 2, 3, and 4, add port 1/1 as a tagged
port to the VLANs, and enable the dual-mode feature and PVST+ support on the port. The
dual-mode feature allows the port to send and receive untagged frames for the default VLAN (VLAN
1 in this case) in addition to tagged frames for VLANs 2, 3, and 4. Enabling the PVST+ support
ensures that the port is ready to send and receive PVST+ BPDUs. If you do not manually enable
PVST+ support, the support is not enabled until the port receives a PVST+ BPDU.
The configuration leaves the default VLAN and the port's native VLAN unchanged. The default
VLAN is 1 and the port's Port Native VLAN also is 1. The dual-mode feature supports untagged
frames on the default VLAN only. Thus, port 1/1 can send and receive untagged BPDUs for VLAN 1
and can send and receive tagged BPDUs for the other VLANs.
BigIron RX Series Configuration Guide
53-1001810-01
CLI Display of PVST+ Information
Untagged IEEE 802.1Q BPDUs on VLAN 1 and tagged PVST+ BPDUs on other VLANs
Tagged IEEE 802.1Q BPDUs on VLAN 1 and untagged BPDUs on another VLAN
32, a PVST+ configuration uses VLAN 1 as the untagged default VLAN and VLANs 2, 3,
Default VLAN 1 for untagged BPDUs
Displays...
The Brocade port number.
NOTE: The command lists information only for the ports on which
PVST+ support is enabled.
The method by which PVST+ support was enabled on the port. The
method can be one of the following:
Set by configuration – You enabled the support.
Set by auto-detect – The support was enabled automatically when
the port received a PVST+ BPDU.
Untagged IEEE BPDU for VLAN 1
Untagged PVST BPDU for VLAN 1
Tagged PVST BPDUs for VLANs 2, 3, 4
Port1/1
PVST/PVST+ compatibility