Dell PowerConnect B-RX Configuration Manual page 502

Bigiron rx series configuration guide v02.7.02
Hide thumbs Also See for PowerConnect B-RX:
Table of Contents

Advertisement

15
Displaying VSRP information
TABLE 81
This field...
state
Administrative-status
Advertise-backup
Preempt-mode
save-current
NOTE: For the following fields:
priority
hello-interval
430
CLI display of VSRP VRID or VLAN information (Continued)
Configured – indicates the parameter value configured on this device.
Current – indicates the parameter value received from the Master.
Unit – indicates the formula used tor calculating the VSRP priority and the timer scales in effect for the VSRP
timers. A timer's true value is the value listed in the Configured or Current field divided by the scale value.
Displays...
This device's VSRP state for the VRID. The state can be one of the
following:
initialize – VSRP is not enabled on the VRID. If the state remains
"initialize" after you enable VSRP on the VRID, make sure that the
VRID is also configured on the other routers and that the routers
can communicate with each other.
NOTE: If the state is "initialize" and the mode is incomplete, make sure
you have specified the IP address for the VRID.
standby – This device is a Backup for the VRID.
master – This device is the Master for the VRID.
The administrative status of the VRID. The administrative status can be
one of the following:
disabled – The VRID is configured on the interface but VSRP or
VRRPE has not been activated on the interface.
enabled – VSRP has been activated on the interface.
Whether the device is enabled to send VSRP Hello messages when it is a
Backup. This field can have one of the following values:
disabled – The device does not send Hello messages when it is a
Backup.
enabled – The device does send Hello messages when it is a
Backup.
Whether the device can be pre-empted by a device with a higher VSRP
priority after this device becomes the Master. This field can have one of
the following values:
disabled – The device cannot be pre-empted.
enabled – The device can be pre-empted.
The source of VSRP timer values preferred when you save the
configuration. This field can have one of the following values:
false – The timer values configured on this device are saved.
true – The timer values most recently received from the Master are
saved instead of the locally configured values.
The device's preferability for becoming the Master for the VRID. During
negotiation, the Backup with the highest priority becomes the Master.
If two or more Backups are tied with the highest priority, the Backup
interface with the highest IP address becomes the Master for the VRID.
The number of units between Hello messages from the Master to the
Backups for a given VRID (1 unit = 100 milliseconds).
BigIron RX Series Configuration Guide
53-1001810-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Brocade dcx-4sBrocade dcx

Table of Contents