clear alarms
Syntax
Command Modes
Command
History
Usage
Information
clear command history
Syntax
Command Modes
Command
History
Related
Commands
configure
Syntax
Parameters
Command Modes
Command
History
Example
40
|
Control and Monitoring
Clear the alarms on the system.
clear alarms
EXEC Privilege
Version 8.3.17.0
Supported on M I/O Aggregator
This command clears alarms that are no longer active. If an alarm situation is still active, it is seen in
the system output.
Clear the command history log.
clear command history
EXEC Privilege
Version 8.3.17.0
Supported on M I/O Aggregator
show command-history
Displays a buffered log of all commands entered by all users along with a
time stamp.
Enter the CONFIGURATION mode from EXEC Privilege mode.
configure [ terminal ]
terminal
(OPTIONAL) Enter the keyword
terminal.
EXEC Privilege
Version 8.3.17.0
Supported on M I/O Aggregator
Figure 5-1. configure Command Example
FTOS#configure
FTOS(conf)#
terminal
to specify that you are configuring from the