Example 3
snmp-server community
Syntax
Parameters
Defaults
Command Modes
Command
History
Usage
Information
Example
Related
Commands
218
|
Simple Network Management Protocol (SNMP) and Syslog
Figure 20-3. show logging driverlog Command Example
FTOS#show logging driverlog stack-unit 1
0:Task(tUsrRoot): [
1:Task(tUsrRoot): [
2:Task(tUsrRoot): [
Fanout ENABLED
3:Task(tUsrRoot): [
4:Task(tUsrRoot): [
5:Task(tUsrRoot): [
6:Task(tUsrRoot): [
7:Task(tUsrRoot): [
8:Task(tUsrRoot): [
9:Task(tUsrRoot): [
10:Task(tUsrRoot): [
11:Task(tUsrRoot): [
12:Task(tUsrRoot): [
13:Task(tUsrRoot): [
configs
14:Task(tUsrRoot): [
15:Task(tUsrRoot): [
16:Task(tUsrRoot): [
17:Task(tUsrRoot): [
18:Task(tUsrRoot): [
19:Task(tUsrRoot): [
20:Task(tUsrRoot): [
Configure a new community string access for SNMPv1, and v2.
snmp-server community community-name { ro }
To remove access to a community, use the no snmp-server community
command.
community-name
ro
none
CONFIGURATION
Version 8.3.17.0
Supported on M I/O Aggregator
configures a community named guest that is mapped to the security named guestuser
Figure 20-4
with Read Only ( ro ) permissions.
Figure 20-4. snmp-server community Command Example
FTOS#config
FTOS(conf)# snmp-server community guest ro
show running-config
45232]SS DRV DEBUG: Wrapper init complete
206775]SS DRV DEBUG: Core init complete
221545]SS DRV DEBUG: SMUX-DRV: BASE MODUEL in
24038]SS DRV DEBUG: port:32 isfanout:1
27]SS DRV DEBUG: port:36 isfanout:1
19]SS DRV DEBUG: port:40 isfanout:0
17]SS DRV DEBUG: port:44 isfanout:0
22]SS DRV DEBUG: port:48 isfanout:1
22]SS DRV DEBUG: port:52 isfanout:1
33]SS DRV DEBUG: Appl init complete
2590]SS DRV DEBUG: Util Init complete
21]SS DRV DEBUG: Device Entry Get Complete
25]SS DRV DEBUG: Sysconf init complete
19]SS DRV DEBUG: Initializing default soc/sal
237]SS DRV DEBUG: sysconf probe complete
118]SS DRV DEBUG: Updating based on Optm
10351]SS DRV DEBUG: Updating based on Fanout
2561]SS DRV DEBUG: unit 0 localWc6 speed10
24]SS DRV DEBUG: unit 0 localWc5 speed10
21]SS DRV DEBUG: unit 0 localWc3 speed40
18]SS DRV DEBUG: unit 0 localWc2 speed40
Enter a text string (up to 20 characters long) to act as a password for SNMP.
ro
Enter the keyword
to specify read-only permission.
Displays the current SNMP configuration and defaults.
community-string
{ ro | rw }

Advertisement