no enable
Disable the default UFD link-tracking configuration.
Syntax
no enable
Defaults
All downstream server-facing ports are brought down when the upstream LAG 128 goes down.
Command Modes
UPLINK-STATE-GROUP-1
Command
Version 8.3.17.4
Supported on M I/O Aggregator
History
Usage
Use the
no enable
command to ensure that server-facing ports on an Aggregator remain up and
Information
continue transmitting traffic without being automatically disabled when LAG 128 connectivity to an
upstream switch/router goes down.
To re-enable the UFD link-tracking configuration, enter the
enable
command in uplink-state-group-1
configuration mode.
Related
uplink-state group 1
Enter the uplink-state group 1 configuration mode.
Commands
240
|
Uplink Failure Detection (UFD)