Dell PowerEdge M I/O Aggregator Reference Manual page 254

Dell poweredge ftos command line reference guide for the m i/o aggregator
Hide thumbs Also See for PowerEdge M I/O Aggregator:
Table of Contents

Advertisement

Defaults
Command Modes
Command
History
Example 1
252
|
Debugging and Diagnostics
cpu data-plane statistics
cpu party-bus statistics
cpu private-mgmt
statistics
drops [ unit 0-0 [ port
1-56
]]
stack-port 33-56
unit 0-0 { counters | details
| port-stats [ detail ] |
register }
none
EXEC
EXEC Privilege
Version 8.3.17.0
Supported on M I/O Aggregator
Figure 25-5. show hardware stack-unit phy-firmware-version Command Example
FTOS#show hardware stack-unit 1 phy-firmware-version
PortNumber
Status
=======================================================================
41
Present
42
Present
43
Present
44
Present
45
Not Present
46
Not Present
47
Not Present
48
Not Present
49
Present
50
Present
51
Present
52
Present
53
Present
54
Present
55
Present
56
Present
FTOS#
cpu data-plane statistics ,
Enter the keywords
keywords stack port and its number — 0 to 52 — to display the data plane
statistics, which shows the High Gig (Higig) port raw input/output counter
statistics to which the stacking module is connected.
cpu party-bus statistics
Enter the keywords
plane input/output counter statistics of the pseudo party bus interface.
cpu private-mgmt statistics
Enter the keywords
Management plane input/output counter statistics of the Private
Management interface.
drops
Enter the
keyword to display internal drops on the selected stack
unit
member. Optionally, use the
port 1-56
then use
to select a port on that port-pipe.
Enter this keyword and a stacking port number to select a stacking port for
which to display statistics. Identify the stack port number as you would to
identify a 10G port that was in the same place in one of the rear modules.
Note: You can identify stack port numbers by physical inspection of
the rear modules. The numbering is the same as for the 10G ports.
You can also inspect the output of the
command.
unit
Enter the
keyword followed by 0 for port-pipe 0, and then enter one of
the following keywords to troubleshoot errors on the selected port-pipe and
to give status on why a port is not coming up to register level:
details , port-stats [ detail ], or register
Programmed Version
01.05
01.05
01.05
01.05
N/A
N/A
N/A
N/A
01.06
01.06
01.06
01.06
01.06
01.06
01.06
01.06
optionally followed by the
, to display the Management
, to display the
keyword with 0 to select port-pipe 0, and
show system stack-ports
counters ,
SW Version
01.05
01.05
01.05
01.05
N/A
N/A
N/A
N/A
01.06
01.06
01.06
01.06
01.06
01.06
01.06
01.06

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge web serverPoweredge xl 5133-4

Table of Contents