Dell PowerEdge M I/O Aggregator Reference Manual page 160

Dell poweredge ftos command line reference guide for the m i/o aggregator
Hide thumbs Also See for PowerEdge M I/O Aggregator:
Table of Contents

Advertisement

vlan tagged
Syntax
Parameters
Defaults
Command Modes
Command
History
Usage
Information
Example
Related
Commands
158
|
Interfaces
Add a Layer 2 interface to a VLAN as a tagged interface.
tagged interface
To remove a tagged interface from a VLAN, use no tagged
interface
Enter the following keywords and slot/port or number information:
For a 10-Gigabit Ethernet interface, enter the keyword
followed by the slot/port information.
All interfaces in Layer 2 mode are untagged.
INTERFACE VLAN
Version 8.3.17.0
Supported on M I/O Aggregator
When you use the no tagged command, the interface is automatically placed in the default VLAN as
an untagged interface unless the interface is a member of another VLAN. If the interface belongs to
several VLANs, you must remove it from all VLANs to change it to an untagged interface.
Tagged interfaces can belong to multiple VLANs, while untagged interfaces can only belong to one
VLAN at a time.
When two or more ports configured for VLANs form a LAG, the resulting LAG is a tagged member of
all the configured VLANs and an untagged member of the VLAN to which the port with the lowest
port ID belongs.
For example, if port 0/33 is an untagged member of VLAN 2 and port 0/41 is an untagged member of
VLAN 3, the resulting LAG consisting of the two ports is an untagged member of VLAN 2 and a
tagged member of VLANs 2 and 3.
Figure 11-34. VLAN Tagged Command Example
FTOS(conf-if-te-0/2)#vlan tagged ?
VLAN-RANGE
FTOS(conf-if-te-0/2)#vlan tagged 2,3-4
FTOS(conf-if-te-0/2)#show config
!
interface TenGigabitEthernet 0/2
mtu 12000
vlan tagged 2-4
!
port-channel-protocol LACP
port-channel 1 mode active
!
protocol lldp
advertise management-tlv system-name
dcbx port-role auto-downstream
no shutdown
FTOS(conf-if-te-0/2)#
interface vlan
Configures a VLAN.
vlan untagged
Specifies which interfaces in a VLAN are untagged.
Comma/Hyphen separated VLAN ID set
interface
command.
TenGigabitEthernet

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge web serverPoweredge xl 5133-4

Table of Contents