Data Center Bridging
Figure 7-9. show interface pfc detail Command Example
FTOS# show interfaces tengigabitethernet 0/49 pfc detail
Interface TenGigabitEthernet 0/49
Admin mode is on
Admin is enabled
Remote is enabled
Remote Willing Status is enabled
Local is enabled
Oper status is recommended
PFC DCBX Oper status is Up
State Machine Type is Feature
TLV Tx Status is enabled
PFC Link Delay 45556 pause quanta
Application Priority TLV
--------------------------------------
FCOE TLV Tx Status is disabled
ISCSI TLV Tx Status is disabled
Local FCOE PriorityMap is 0x8
Local ISCSI PriorityMap is 0x10
Remote FCOE PriorityMap is 0x8
Remote ISCSI PriorityMap is 0x8
0 Input TLV pkts, 1 Output TLV pkts, 0 Error pkts, 0 Pause Tx pkts, 0 Pause
Rx pkts
Table 7-3
lists the show interface pfc summary field descriptions.
Table 7-3. show interfaces pfc summary Command Example Fields
Field
Description
Interface
Interface type with stack-unit and port number.
Admin mode is on
PFC mode: on or off.
Admin is enabled
Priority list: list of the configured PFC priorities (if any).
When the PFC admin mode is on, PFC advertisements are enabled to be sent and
received from peers.
Remote is enabled,
Remote Admin mode: (enabled if a valid TLV was received or disabled)
Priority list,
Priority list: list of the configured PFC priorities (if any).
Remote Willing Status is
Remote Willing Status: Willing bit received in PFC TLVs from the remote peer.
enabled
Local is enabled
Local PFC configuration including the mode and the list of PFC priorities
configured.
Operational status (local
Port state for current operational PFC configuration:
port)
PFC DCBX Oper status
Operational status for the exchange of the PFC configuration on the local port:
match (up) or mismatch (down).
State Machine Type
Type of state machine used for DCBX exchanges of the PFC parameters:
Feature - for legacy DCBX versions; Symmetric - for an IEEE version.
TLV Tx Status
Status of the PFC TLV advertisements: enabled or disabled.
Parameters :
Init: Local PFC configuration parameters were exchanged with the peer.
Recommend: Remote PFC configuration parameters were received from the
peer.
Internally propagated: PFC configuration parameters were received from the
configuration source.