• Re-lnit Delay (1-10)
• Tx Delay (1-8192)
Button
: press this button to take effect
Therefore, the default TTL is 4*30 = 120 seconds.
This column provides configuring Re-lnit Delay settings; the default value is 2
and the available range is 1 to 10. Unit is second.
When a port is disabled, LLDP is disabled or the Managed PoE+ Switch is
rebooted a LLDP shutdown frame is transmitted to the neighboring units,
signaling that the LLDP information isn't valid anymore. Re-init Delay controls
the amount of seconds between the shutdown frame and a new LLDP
initialization.
This column provides configuring Tx Delay settings; the default value is 2 and
the available range is 1 to 8192. Unit is second.
If some configuration is changed (e.g. the IP address) a new LLDP frame is
transmitted, but the time between the LLDP frames will always be at least the
value of Tx Delay seconds. Tx Delay cannot be larger than 1/4 of the Tx
Interval value.
This attribute must comply with the rule:
(4 * Delay Interval) ≤Transmission Interval