Cbr - Paradyne Hotwire 8300 User Manual

Endpoint
Hide thumbs Also See for Hotwire 8300:
Table of Contents

Advertisement

LOSWS
Count of Loss of Sync Word Seconds on this endpoint since the xU was last
restarted.
SES
Count of Severely Errored Seconds on this endpoint since the unit was last
restarted.
UAS
Count of Unavailable Seconds on this endpoint since the xU was last restarted.
1 5 - M i n u t e a n d 1 - D a y I n t e r v a l s
Also included on this screen are prompts that, when selected, display the span
endpoint performance summaries for 15-minute intervals and for 1-day intervals.
These screens display only a summary of the errors (ES, SES, CRC, LOSWS,
UAS) that have occurred on the span during the interval selected.
The 15-Minute Intervals table provides one row for each endpoint performance
data collection 15-minute interval. The 1-Day Intervals screen provides one row for
each endpoint performance data collection 24-hour interval.

CBR

The CBR screen
interface's configuration as described below. In addition, this screen provides a
table that displays error status and alarm thresholds for the CBR interface.
Figure 3-16. CBR Screen
T1/E1 Framing
Selects the framing for the network side of the DSU/CSU.
8300-A2-GB20-00
(Figure
3-16) lets you view and make changes to the CBR
Values: T1 ESF, T1 D4, E1 CCS, E1 CAS
E1 Unframed, T1 Unframed
Default: E1 CCS
April 2003
3. VT100 Interface
3-17