2. Web Server Interface
upper threshold levels are used in conjunction with Cell Delay Variation to provide
hysteresis around threshold levels.
AAL1 Format
Specifies AAL1 format
be set in accordance with the Format Relationships Table
page 2-38 for proper operation.
Payload
The 8300 Endpoint scrambles/descrambles cell payload bytes at the physical
layer interface using an x
Scrambling
scrambling function on the CES Service Details Screen. Normal operation will
have Payload Scrambling enabled. (See Figure 2-32. on page -35.)
Partial Cell Fill Byte
Sets the number of user octets per cell. Setting this parameter to 0 disables Partial
Cell Fill, and all cells are completely filled before being sent.
Count
Rx Cell Delay
Maximum cell arrival jitter in 10-
Variation (10
s )
tolerate in the cell stream without producing errors on the CBR service interface.
µ
Default is 100 for a 1000-
Cell Loss
Time in milliseconds for the cell loss integration period. If cells are continuously
Integration (ms)
lost during the specified period of time, Cell Loss Status is set to Loss. Default is
2500 ms.
Administrative
Sets the Administrative Status of the CES IWF. Up indicates traffic flow is enabled,
Status
and Down indicates traffic flow is disabled across the CES IWF.
NOTICE:
Operational Status
Displays the Operational Status of the CES IWF. The state will be Down or
Unknown if the supporting CBR or ATM interface is down or unknown.
Status
Reassembly Cells
Displays the number of cells received by the CES IWF. This number excludes cells
that have been discarded for any reason, including cells not used due to their
being misinserted or discarded while the reassembler was awaiting
synchronization.
Header Errors
Displays the number of AAL1 header errors detected, including those that have
been corrected. Header errors include correctable and uncorrectable CRCs and
bad parity.
2-36
Values: Synchronous, Adaptive
Default: Synchronous
Basic, E1Cas, Ds1SfCas, or Ds1EsfCas. This value must
43
s Cell Delay Variation (CDV).
µ
To enable a new parameter, rather than saving and restarting, set
the Administrative Status to Down, and click on the Submit button at
the bottom of the screen. Then set the Administrative Status to Up,
and click on the Submit button once again.
April 2003
+ 1 polynomial. You may enable/disable the
s increments that the reassembly process will
µ
(Table
2-1) on
8300-A2-GB20-00

Advertisement

Table of Contents
loading

Table of Contents