Paradyne Hotwire 8300 User Manual page 125

Endpoint
Hide thumbs Also See for Hotwire 8300:
Table of Contents

Advertisement

Figure 3-21. Serial Screen
Type
Selects the type of interface (based on its electrical signal characteristics) used by
the equipment connected to the Serial port.
NOTICE:
Mode
By default, the Serial port serves as a DCE port. However, the Serial port can
serve as a DTE port.
If the Serial port connects to a DTE device (such as a FRAD or a router), the Mode
parameter must be set to DCE. If this port connects to a DCE device (such as a
DSU/CSU), this parameter must be set to DTE.
NOTICE:
NOTICE:
Packet Rate
Packet Rate must be configured to the desired port speed (in bits per second).
Bundling
Selects whether the DTE channel assignment is made as a Contiguous group or
as Alternate channels. Selecting Alternate ensures ones density. Because the unit
allows individual channels to be configured for a service, a value of Arbitrary will
8300-A2-GB20-00
Values: V.35, V.36, RS-232, EIA-530, and X.21
Default: V.35
V.35 requires the use of an optional cable. Refer to
Assignments
in Appendix A, Specifications for ordering information.
Values: DCE, DTE
Default: DCE
DTE mode requires the use of an optional DTE cable. Refer to
Connector Pin Assignments
ordering information.
When you configure the Serial port for CES, you must set the port
mode to DCE.
Values: 64
2 304 kbps
Default: 2048 kbps
April 2003
3. VT100 Interface
Connector Pin
in Appendix A, Specifications for