Serial CES Configuration
The 8300 Endpoint has the capability to multiplex/demultiplex the Serial interface
data stream with the CBR interface data stream. The multiplexing/demultiplexing
is external to the AAL1 SAR; the user controls it by designating time slots for the
CES service on the CBR or Serial port. To configure the Serial interface for CES
service, perform the following steps:
Valid Channel Ranges for Serial and CBR Interfaces
The range of channels available to the Serial interface depends on the type of
CES service. The table below shows the range of channels available to the Serial
and CBR interfaces for each type of CES service. The type of CES service and the
SHDSL data rate shown in Maximum CES Channels
the total number of channels that can be allocated to the Serial interface.
8300-A2-GB20-00
1. On the Services screen (page 2-25), click on the Service Index associated
with the Serial interface (5). This will cause the unit to display the Service
Details screen for the Serial interface. On the Service Details screen
(page 2-26), select CES from the Type pull-down menu.
2. On the Serial screen (page 2-19), configure the Serial interface to your
requirements. You must set the Mode parameter to DCE. If the required time
slots for the Serial interface are contiguous and not already allocated to the
CBR port, you may allocate the required channels on the Serial screen. If you
have not allocated channels for the Serial interface on the Serial screen, use
the Channel Table Details screen (Step 3 below) to specify the channels for
the Serial CES service.
3. On the Channel Table Details screen (page 2-38), set the desired channel's
Rate parameter to 64K, and the Service parameter to the Service Index for the
Serial interface (5).