3. VT100 Interface
15-minute collection interval reaches/exceeds this value, a trap is generated. One
trap will be sent per interval per endpoint. A value of 0 (zero) disables the trap.
CRC
Sets the threshold for the number of Cyclic Redundancy Check anomalies within
any given 15-minute performance data collection interval. If the value of CRC
anomalies in a particular 15-minute collection interval reaches/exceeds this value,
a trap is generated. One trap will be sent per interval per endpoint. A value of 0
(zero) disables the trap.
LOSWS
Sets the threshold for the number of Loss of Sync Word Seconds within any given
15-minute performance data collection interval. If the value of LOSW in a
particular 15-minute collection interval reaches/exceeds this value, a trap is
generated. One trap will be sent per interval per endpoint. A value of 0 (zero)
disables the trap.
UAS
Sets the threshold for the number of Unavailable Seconds within any given
15-minute performance data collection interval. If the value of UAS in a particular
15-minute collection interval reaches/exceeds this value, a trap is generated. One
trap will be sent per interval per endpoint. A value of 0 (zero) disables the trap.
Span Endpoints Screen
Selecting the Span Endpoints prompt on the 8300 Endpoint Network screen will
display the screen shown in
Figure
3-12.
Figure 3-12. Span Endpoints Screen
This screen displays each endpoint of the span. If the SHDSL link is not up, only
the local side of the span is displayed. The EOC channel is used to access the
remote end unit
The Span Endpoints Details screen
(Figure
3-13, accessed by selecting from the
<Unit> column) supports retrieval of unit inventory information available via the
EOC from units on an SHDSL line, and provides details regarding the parameters
listed below.
3-13