1. About the Hotwire 8300 Endpoint

Front Panel

The front panel of the 8300 Endpoint is shown below in Figure 1-1.
Figure 1-1.
The front panel's five LED status indicators are described below:
1-6
Front Panel of 8300 Endpoint
Indicator
Description
MODE
Normally, this indicator lights green .
The indicator lights amber while configuration is being set by the front
panel buttons or when the configuration is changed by SNMP or through
the web interface. The indicator will remain amber until the changed
configuration is saved; it will revert to green when the new configuration
has been saved.
The indicator is off (not illuminated) when the CBR port has not been
C B R
configured.
The indicator lights green when the CBR port link is up and is receiving
AAL1 cells.
The indicator lights red when the CBR port has been configured and no
AAL1 cells are received.
The indicator lights amber when the CBR port link is up but AAL1 cells
are not being received.
NET
The indicator is off (not illuminated) when the Network port has not been
configured.
The indicator lights green when the Network port link is up and the ATM
protocol is established.
The indicator lights red when the Network port link is down and the ATM
protocol is not established.
The indicator lights amber when the Network port link is up, but the ATM
protocol is not established.
The indicator lights red if an alarm condition exists.
A L A R M
The indicator lights amber if a yellow alarm condition exists.
The indicator lights green when power is applied to the unit.
P O W E R
The indicator lights amber when the unit is in a test mode loopback.
April 2003
8300-A2-GB20-00