3. VT100 Interface
SES
Severely Errored Seconds threshold.
CRC
Cyclic Redundancy Check anomalies threshold.
LOSWS
Loss of Sync Word Second threshold.
UAS
Unavailable Seconds Threshold.
A l a r m P r o f i l e D e t a i l s S c r e e n
Select from the <Alarm Profiles> column on the above screen to display a screen
similar to the one shown in
the alarm threshold values to be used for the selected alarm profile.
Figure 3-11. Alarm Profile Details Screen
Profile Name
Displays the name associated with this Endpoint Alarm profile.
Loop Attenuation
Sets the loop attenuation alarm threshold. If the current value reaches or exceeds
this threshold, a crossing trap is generated. A value of 0 (zero) disables the trap.
SNR Margin
Sets the Signal-to-Noise Ratio margin alarm threshold. When the current SNR
value reaches or drops below this threshold, a crossing trap is generated. A value
of 0 (zero) disables the trap.
ES
Sets the threshold for the number of Errored Seconds within any given 15-minute
performance data collection interval. If the value of ES in a particular 15-minute
collection interval reaches/ exceeds this value, a trap is generated. One trap will
be sent per interval per endpoint. A value of 0 (zero) disables the trap.
SES
Sets the threshold for the number of Severely Errored Seconds within any given
15-minute performance data collection interval. If the value of SES in a particular
3-12
Figure
3-11. The table on this screen lets you configure
April 2003
8300-A2-GB20-00