Flow Control
Selects the type of flow control to be used if the port is asynchronous.
Character Size
Selects the number of bits required to make up one asynchronous character.
Parity
Sets the parity bit.
Stop Bit
Selects the number of bits required to end the asynchronous character.
RTS
Request To Send determines the source from which the unit reads the RTS signal
status. If set to Normal, the unit gets RTS from the DTE on the Serial interface. If
set to Forced True, RTS is always perceived as On.
RTS/CTS Delay
Request To Send/Clear To Send determines how long the unit waits before it
changes the level of CTS to match RTS when the CTS parameter is set to Internal.
CTS
Clear to Send can be set to Forced True, Forced False, or Internal. If this
parameter is set to Internal, the CTS control lead follows the RTS control lead from
the DTE after a delay of a duration established by the RTS/CTS Delay parameter
(see above).
DCD
Data Carrier Detect parameter can be set to Forced True, Forced False, or
Internal. If set to Internal, DCD is On when network carrier is being received from
the remote end, and is Off when network carrier is not being received from the far
end.
DSR
Data Set Ready can be set to Forced True, Forced False, or Internal. The Internal
option sets DSR On if the port is enabled and Off if the port is disabled.
8300-A2-GB20-00
Values: None, Xon/Xoff, RTS/CTS
Default: None
Values: Five, Six, Seven, Eight
Default: Eight
Values: None, Odd, Even
Default: None
Values: 1, 2
Default: 1
Values: Normal, Forced True
Default: Normal
Values: Normal (~30 ms delay), Long (~100 ms delay)
Default: Normal
Values: Forced True, Forced False, Internal
Default: Forced True
Values: Forced True, Forced False, Internal
Default: Forced True
Values: Forced True, Forced False, Internal
Default: Forced True