Reference Manual
SYSTEM INITIALIZATION AND SHUTDOWN
*** ADRV9001 Pre-Calibrate System Debugging Started ***
--> . Hardware Reset
OK
--> . API Version
OK - API Version = 67.3.2
--> . Configure SPI
OK
--> . Check SPI
OK
--> . Check Power Supplies
OK
--> . ARM Image Load
Started Reading Binary Image
Completed Reading Binary Image
OK
--> . Check ARM Image Load
OK
--> . Check Dev_Clk
OK
--> . Load SP
Started Reading Binary Image
Completed Reading Binary Image
OK
--> . Check SP
OK
*** ADRV9001 Pre-Calibrate System Debugging Completed ***
*** ADRV9001 Post-Calibrate System Debugging Started ***
--> . Check RF PLLs
OK
*** ADRV9001 Post-Calibrate System Debugging Completed ***
Table 13
shows the two APIs associated with this feature: one each for precalibration and post-calibration checks.
Table 13. APIs for Precalibration and Post-Calibration Checks
API Function
adi_adrv9001_Utilities_SystemDebugPreCalibrate()
adi_adrv9001_Utilities_SystemDebugPostCalibrate()
analog.com
Description
Function for in-system debugging (precalibration)
Function for in-system debugging (post-calibration)
ADRV9001
Rev. 0 | 46 of 351