TOHATSU MD 30B2 Service Manual page 310

Hide thumbs Also See for MD 30B2:
Table of Contents

Advertisement

O
Troubleshooting
K
Before working on the engine, check that hull, rigging and engine installation are normal, and then
battery is fully charged.For mechanical troubleshooting, refer to relevant troubleshooting section in
this chapter. For checking and servicing outboard motor, refer to service procedures described in this
manual to perform the work safely.
Power Unit
State 1
Engine will not start or is hard to start.
Check that gear shift is
in neutral (N).
Neutral (N)?
YES
Check if starter motor
operates.
Operates?
NO
Check battery cables for
defective contact, ground lead
wire securing bolt for
looseness or disconnection,
starter motor positive terminal
for break, and fuse if it is blow.
Normal?
YES
Check operations of
starter solenoid.
Normal?
YES
Go to next page.
9-14
Starting System
NO
YES
NO
NO
Shift into neutral (N).
Check ignition system
and/or fuel system.
Repair or replace
defective parts.
Replace starter
solenoid.
TLD D30/40/50B2 2013

Advertisement

Table of Contents
loading

This manual is also suitable for:

Md 40b2Md 50b2D40b2zWd50b2

Table of Contents