Lower Unit
7) Removing Water Pump
1.
Loosen and remove pump case (upper) bolts, and remove
pump case (upper) parts 1, 2, 3 and 4 in this order.
2.
Remove water pump impeller key 5.
3.
Remove guide plate 6, gasket 7 and pump case (lower)
8.
When removing pump case (lower), insert bladed
screw driver into the groove of the case, and pry
slowly to separate the part.
6-16