12) Installation of FFP Ass'y to Cylinder
1.
Put fuel hose 3, fuel return hose 4 and vapor return hose
5 and secure them by using hose clips.
2.
Attach FFP Ass'y 1 by using bolt 2.
Bolt 2 :
6 N·m (4 lb·ft) [0.6 kgf·m]
3.
Attach high pressure fuel hose 6 to FFP 1.
High Pressure Fuel Hose Nut 6 :
15 N·m (11 lb·ft) [1.5 kgf·m]
Connect FFP cord connector (cord ass'y) 7 and secure it
with clamp 8.
Use clamp of FFP ass'y to secure FFP cord
connector.