11) Inspection of Rectifier Complete
1.
Measure resistance between terminals.
This test can be made without removing parts.
Rectifier Tester Check Table
Red
Black
(4.2kΩ)
Yellow
(3.5kΩ)
Yellow
(3.5kΩ)
Yellow
(3.5kΩ)
Notes:
1 Use HIOKI HiTESTER MODEL 3030 or equivalent tester for this measurement, and do not use megger or
other instrument.
2 Disconnect all connections, and measure as an independent unit.
3 When the tester's pointer moves, the result is "ON", or "OFF" when not.
4 The value enclosed by ( ) is approximately value measured using 1kΩ range of the tester. Note that the value
varies among conditions of the tester (internal power supply), measurement ranges and models.
5 Perform this inspection only as a guide.
TLD D30/40/50B2 2013
Positive Tester Lead (Red)
Red
Black
OFF
ON
ON
ON
(2.4kΩ)
ON
ON
(2.4kΩ)
ON
ON
(2.4kΩ)
a Yellow
b Red
c Black
"ON" means conductive and "OFF" means no conductivity.
Yellow
Yellow
OFF
OFF
ON
ON
(2.3kΩ)
(2.3kΩ)
ON
(4.8kΩ)
ON
(4.8kΩ)
ON
ON
(4.8kΩ)
(4.8kΩ)
a
a
b
b
c
c
Yellow
OFF
ON
(2.3kΩ)
ON
(4.8kΩ)
ON
(4.8kΩ)
8