TOHATSU MD 30B2 Service Manual page 146

Hide thumbs Also See for MD 30B2:
Table of Contents

Advertisement

Power Unit
8.
Remove solenoid bracket and electric sub ass'y from
power unit.
Note that grounding wire of cord ass'y is secured
together.
9.
Disconnect ECU connectors while pushing hook of ECU
connector and pull apart.
10.
After removing top two ECU mount rubber bolts, remove
ECU by pulling it upward.
11.
Loosen band that secures cord ass'y, and then, remove
cord ass'y from power unit.
• Note that grounding wire of cord ass'y is secured
together.
• Refer to "Electrical Wiring Assembling Instruction
Diagrams" in Chapter 11.
5-24