Canon imageRUNNER ADVANCE C5255 Series Service Manual page 967

Hide thumbs Also See for imageRUNNER ADVANCE C5255 Series:
Table of Contents

Advertisement

COPIER > FUNCTION > SYSTEM
DSRAMRES
Restore of DC Controller PCB SRAM
Lv.2 Details
To restore the setting data which has been backed up in SRAM of the
DC Controller PCB.
Use case
When replacing the DC Controller PCB for troubleshooting at the time
of problem occurrence
Adj/set/operate method Select the item, and then press OK key.
Caution
During operation, the setting data changes by manual or automatic
adjustment. When backup data which has been left for a long period of
time is restored, it is overwritten with new setting data and the old data
is deleted.
Display/adj/set range
During operation: ACTIVE, When operation finished normally: OK!
Related service mode
COPIER> FUNCTION> SYSTEM> DSRAMBUP
RSRAMBUP
Backup of Reader Controller PCB SRAM
Lv.2 Details
To back up the setting data in SRAM of the Reader Controller PCB.
Use case
When replacing the Reader Controller PCB for troubleshooting at the
time of problem occurrence
Adj/set/operate method Select the item, and then press OK key.
Caution
During operation, the setting data changes by manual or automatic
adjustment. When backup data which has been left for a long period of
time is restored, it is overwritten with new setting data and the old data
is deleted.
Display/adj/set range
During operation: ACTIVE, When operation finished normally: OK!
Related service mode
COPIER> FUNCTION> SYSTEM> RSRAMRES
RSRAMRES
Restore of Reader Controller PCB SRAM
Lv.2 Details
To restore the setting data which has been backed up in SRAM of the
Reader Controller PCB.
Use case
When replacing the Reader Controller PCB for troubleshooting at the
time of problem occurrence
Adj/set/operate method Select the item, and then press OK key.
Caution
During operation, the setting data changes by manual or automatic
adjustment. When backup data which has been left for a long period of
time is restored, it is overwritten with new setting data and the old data
is deleted.
Display/adj/set range
During operation: ACTIVE, When operation finished normally: OK!
Related service mode
COPIER> FUNCTION> SYSTEM> RSRAMBUP
R-REBOOT
Reboot of host machine: remote
Lv.1 Details
To reboot the host machine by remote control via RUI.
Use case
When rebooting the host machine by remote control
8
Service Mode > COPIER > FUNCTION > SYSTEM
T-8-49
8
Service Mode > COPIER > FUNCTION > SYSTEM
8-147
8-147