Canon imageRUNNER ADVANCE C5255 Series Service Manual page 785

Hide thumbs Also See for imageRUNNER ADVANCE C5255 Series:
Table of Contents

Advertisement

E
Detailed
Occurance
Items
code
code
area
E748 2011
00
Title
Error in Flash PCB
Description Unable to find the kernel.
Remedy
Contact to the sales companies.
E748 2012
00
Title
Error in Flash PCB
Description Unable to mount the Linux system at starting service
mode, or there is no system start script.
Remedy
Contact to the sales companies.
E748 2021
00
Title
Error in access of Main Controller PCB 2
Description Necessary H/W on the Main Controller PCB 2 is not
found.
Remedy
1. Clean the terminal of the Main Controller PCB 2, and
disconnect and then connect it.
2. Clean the terminal of the Main Controller PCB 1, and
disconnect and then connect it.
3. Replace the Main Controller PCB 2.
E748 2022
00
Title
Error in access of Main Controller PCB 2
Description Necessary H/W on the Main Controller PCB 2 is not
found.
Remedy
1. Remove and then insert the Main Controller PCB 1
and the Main Controller PCB 2 .
2. Replace the Main Controller PCB 1 and the Main
Controller PCB 2.
E748 2023
00
Title
Error in access of Main Controller PCB 2
Description Unable to initialize the memory DDR2-SDRAM on the
Main Controller PCB 2.
Remedy
1. Clean the terminal of the DDR2-SDRAM , and
disconnect and then connect it.
2. Replace the DDR2-SDRAM.
E748 2024
00
Title
Error in access of Main Controller PCB 2
Description CPU on the Main Controller PCB 2 fails to complete the
initialization.
Remedy
1. Clean the terminal of DDR2-SDRAM, and remove and
then install the DDR2-SDRAM.
2. Check power state of Main Controller PCB 2 and
check around the connector.
3. Check power state of the Riser PCB and check around
the connector.
4. Replace the Main Controller PCB 2.
5. Replace the Riser PCB.
6. Replace the Main Controller PCB 1.
E748 2025
00
Title
Error in access of Main Controller PCB 2
Description Disconnection of the Bypass PCB was detected.
Remedy
Remove and then install the Bypass PCB.
7
Error•Jam•Alarm > Error Code > Error Code Details
Description
7
Error•Jam•Alarm > Error Code > Error Code Details
E
Detailed
Occurance
Items
code
code
area
E748 2026
00
Title
Error in access of Main Controller PCB 2
Description Disconnection of the Image Processing Sub PCB was
detected.
Remedy
Remove and then install the Image Processing Sub PCB.
E748 9000
00
Title
System error
Description System error
Remedy
Contact to the sales companies.
E749 0006
00
Title
Restart direction due to configuration change.
Description The option such as the Finisher and Paper Deck was
installed or removed when all of following conditions were
met and the machine configuration is changed when the
main power switch is turned ON.
- Settings/Registration > Preferences > Timer/Energy
Settings > Quick Startup at Power-on > ON
- The Main Power Switch is turned OFF
- The power plug of the machine is connected to the
output.
- The breaker is ON
Remedy
It is recovered by turning OFF and then ON the main
power.
CAUTION
This machine provides power to some PCBs even when
in the main power OFF status.
The power supply is not completely OFF by just turning
OFF the main power switch and therefore, the machine is
unable to detect a configuration change.
When disconnecting and then connecting a connector,
always disconnect the power plug or turn the breaker
OFF.
Refer to the Service Manual > Chapter 2 > External and
Controls > Quick Startup for details.
7-94
Description
7-94

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents