Canon imageRUNNER ADVANCE C5255 Series Service Manual page 537

Hide thumbs Also See for imageRUNNER ADVANCE C5255 Series:
Table of Contents

Advertisement

5
Adjustment > Pickup Feed System > Geometric Characteristics Adjustment > Fixing Alignment Adjustment
■ Fixing Alignment Adjustment
Adjustment is possible by loosening the screw located as shown in the figure below and
moving the Adjustment Plate up and down. Check the position of the Adjustment Plate before
adjustment.
The range which can be adjusted by this adjustment is maximum approx. 0.3mm. (Differs
according to the paper type)
Symptom
The right side of the trailing edge of
image is distorted.
The left side of the trailing edge of
image is distorted.
Note:
This procedure cannot be performed correctly when the Fixing Assembly is installed. Be
sure to remove the Fixing Assembly at adjustment.
5
Adjustment > Pickup Feed System > Geometric Characteristics Adjustment > Fixing Alignment Adjustment
Operation
Move the Adjustment Plate up.
Move the Adjustment Plate down.
T-5-16
Adjustment
Plate
Evaluation
Objective
F-5-7
• When the right side of the trailing edge of image is distorted
Move the Adjustment Plate up.
Loosen
Feed direction
• When the left side of the trailing edge of image is distorted
Move the Adjustment Plate down.
Loosen
Feed direction
5-10
F-5-8
F-5-9
5-10