Adjustment > Pickup Feed System > Geometric Characteristics Adjustment > Registration Roller Pressure Adjustment
■ Registration Roller Pressure Adjustment
Adjustment is possible by turning the screw located as shown in the figure below. Check the
position of the Adjustment Plate before adjustment.
The range which can be adjusted by this adjustment is maximum approx. 0.3mm. (Differs
according to the paper type)
Symptom
Operation
The left side of the trailing
Turn the screw
edge of image is distorted.
counterclockwise.
The right side of the trailing
Turn the screw clockwise.
edge of image is distorted.
5
Adjustment > Pickup Feed System > Geometric Characteristics Adjustment > Registration Roller Pressure Adjustment
Points to check
The Adjustment Plate moves
to the right.
The Adjustment Plate moves
to the left.
T-5-15
Screw
Adjustment
Plate
Evaluation
Objective
F-5-4
• When the left side of the trailing edge of image is distorted
Turn the screw counterclockwise.
Feed direction
• When the right side of the trailing edge of image is distorted
Turn the screw clockwise.
Feed direction