Canon imageRUNNER ADVANCE C5255 Series Service Manual page 557

Hide thumbs Also See for imageRUNNER ADVANCE C5255 Series:
Table of Contents

Advertisement

■ E732-0023: Scanner communication error
[Description]
A communication error between the Reader Controller PCB and the Main Controller PCB 2
was detected at startup/recovery from sleep.
[Remedy]
Start remedy for error
at startup
It is highly possible that signal
Check if the Reader/ADF operates
is not detected normally
when turning ON the power.
between the Reader/ADF and
the Main Controller.
Yes
Does it operate?
There is a possibility
No
that power is not supplied
to the Reader/ADF.
Check (connection and
conduction state of)/replace
the harness/cable, connector
and parts related to
power supply. (Refer to
[Related parts 2: Power supply].)
No
Is the error cleared?
Collect Sublog and contact
Yes
to the sales company.
NOTE:
If the cause of the error cannot be
identified by analyzing Sublog,
it may require
End
investigation separately.
6
Troubleshooting > Troubleshooting items > Error Code > E732-0023: Scanner communication error
Check (connection and conduction
state of)/replace the harness/cable,
connector and parts related to
communication.
(Refer to
[Related parts 1: Communication].)
No
Is the error cleared?
Yes
End
6
Troubleshooting > Troubleshooting items > Error Code > E732-0023: Scanner communication error
[Related parts 1: Communication]
• Harness between the Main Controller PCB 2 (J3003) and the Reader Controller PCB (PCB1/
J109) (Unit of replacement: CABLE, INTERFACE)
• Main Controller PCB 2 (Unit of replacement: MAIN CONTROLLER PCB ASS'Y, 2)
• Reader Controller PCB (PCB1) (Unit of replacement: READER CONTROLLER PCB
ASSEMBLY)
[Related parts 2: Power Supply]
• - Harnesses from the Relay PCB to the Reader Controller PCB
• 1. Relay PCB (UN5/J426) to Relay Connector (6P) (Unit of replacement: CABLE, DC
POWER SUPPLY)
• 2. Relay Connector (6P) to Reader Controller PCB (PCB1/J101) (Unit of replacement:
CABLE, READER POWER SUPPLY)
• Reader Controller PCB (PCB1) (Unit of replacement: READER CONTROLLER PCB
ASSEMBLY)
• Relay PCB (UN5) (Unit of replacement: RELAY PCB ASSEMBLY)
[Reference]
Before replacing the Reader Controller PCB, back up the service mode data (approx. 2 min)
and restore the backup data after the replacement so the data may be able to be protected.
• Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMBUP
• Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMRES