■ ANALOG
COPIER > DISPLAY > ANALOG
TEMP
Display of outside temperature
Lv.1 Details
To display the temperature outside the machine.
This is measured by the Environment Sensor 2 that detects the
outside air.
Use case
When checking the temperature outside the machine
Display/adj/set range
0 to 50
Unit
deg C
Appropriate target value 20 to 27
HUM
Display of outside humidity
Lv.1 Details
To display the humidity outside the machine.
This is measured by the Environment Sensor 2 that detects the
outside air.
Use case
When checking the humidity outside the machine
Display/adj/set range
0 to 100
Unit
%
Appropriate target value 30 to 70
ABS-HUM
Display of outside moisture amount
Lv.1 Details
To display the absolute moisture content outside the machine.
This is measured by the Environment Sensor 2 that detects the
outside air.
Use case
When checking the moisture content outside the machine
Display/adj/set range
0 to 100
Unit
g/m3
Appropriate target value 0 to 22
FIX-C
Display of Fixing Film temperature
Lv.1 Details
To display the center temperature of the Fixing Film detected by the
Main Thermistor 2.
Use case
When checking the temperature of Fixing Film
Display/adj/set range
0 to 300
Unit
deg C
FIX-E
Dis of Fixing Heater center temperature
Lv.1 Details
To display the center temperature of the Fixing Heater detected by
the Main Thermistor 1.
Use case
When checking the temperature at the center of Fixing Heater
Display/adj/set range
0 to 300
Unit
deg C
FIX-E2
Dis of Fixing Heater front edge temp
Lv.1 Details
To display the front edge temperature of the Fixing Heater detected
by the Sub Thermistor 1.
Use case
When checking the edge temperature of the Fixing Heater
Display/adj/set range
0 to 300
Unit
deg C
8
Service Mode > COPIER > DISPLAY > ANALOG
8
Service Mode > COPIER > DISPLAY > ANALOG
COPIER > DISPLAY > ANALOG
TEMP2
Display of inside temperature
Lv.1 Details
To display the temperature inside the machine measured by the
Environment Sensor 1.
Use case
When checking the temperature inside the machine
Display/adj/set range
0 to 100
Unit
deg C
Appropriate target value 20 to 27
HUM2
Display of inside humidity
Lv.1 Details
To display the humidity inside the machine measured by the
Environment Sensor 1.
Use case
When checking the humidity inside the machine
Display/adj/set range
0 to 100
Unit
%
Appropriate target value 30 to 70
FIX-E3
Dis of Fixing Heater rear edge temp
Lv.1 Details
To display the rear edge temperature of the Fixing Heater detected
by the Sub Thermistor 2.
Use case
When checking the edge temperature of the Fixing Heater
Display/adj/set range
0 to 300
Unit
deg C
8-32
T-8-6
8-32