E020
0011
05
Title
Error in Y Developing Assembly
Description Patch level is higher than the target upper limit although
the patch level was minimized at the time of patch
initialization.
Remedy
Go through the following: DISPLAY > P-LED-DA; perform
cleaning first If P-LED-DA is 3F or more.
1. Check installation of the Developing Assembly and the
Drum.
2. Clean the Patch Sensor (UN47,UN48,UN49) Window.
3. Replace the Patch Sensor.
4. Replace the Drum.
E020
0012
05
Title
Error in M Developing Assembly
Description Patch level is higher than the target upper limit although
the patch level was minimized at the time of patch
initialization.
Remedy
Go through the following: DISPLAY > P-LED-DA; perform
cleaning first If P-LED-DA is 3F or more.
1. Check installation of the Developing Assembly and the
Drum.
2. Clean the Patch Sensor (UN47,UN48,UN49) Window.
3. Replace the Patch Sensor.
4. Replace the Drum.
E020
0013
05
Title
Error in C Developing Assembly
Description Patch level is higher than the target upper limit although
the patch level was minimized at the time of patch
initialization.
Remedy
Go through the following: DISPLAY > P-LED-DA; perform
cleaning first If P-LED-DA is 3F or more.
1. Check installation of the Developing Assembly and the
Drum.
2. Clean the Patch Sensor (UN47,UN48,UN49) Window.
3. Replace the Patch Sensor.
4. Replace the Drum.
7
Error•Jam•Alarm > Error Code > Error Code Details
Description
7
Error•Jam•Alarm > Error Code > Error Code Details
E
Detailed
Occurance
Items
code
code
area
E020
0014
05
Title
Error in Bk Developing Assembly
Description Patch level is higher than the target upper limit although
the patch level was minimized at the time of patch
initialization.
Remedy
Go through the following: DISPLAY > P-LED-DA; perform
cleaning first If P-LED-DA is 3F or more.
1. Check installation of the Developing Assembly and the
Drum.
2. Clean the Patch Sensor (UN47,UN48,UN49) Window.
3. Replace the Patch Sensor.
4. Replace the Drum.
E020
0021
05
Title
Error in Y Developing Assembly
Description Patch level is lower than the target lower limit although
the patch level was maximized at the time of patch
initialization.
Remedy
Go through the following: DISPLAY > P-LED-DA; perform
cleaning first if P-LED-DA is 3F or more.
If the Patch Sensor (UN47, UN48,UN49) value shows
1-digit, check that the Developing Assembly is installed,
and then perform remedy from "3".
1. Check installation of the Developing Assembly and the
Drum.
2. Clean the Patch Sensor Window.
3. Replace the Patch Sensor.
4. Replace the Drum.
E020
0022
05
Title
Error in M Developing Assembly
Description Patch level is lower than the target lower limit although
the patch level was maximized at the time of patch
initialization.
Remedy
Go through the following: DISPLAY > P-LED-DA; perform
cleaning first if P-LED-DA is 3F or more.
If the Patch Sensor (UN47, UN48,UN49) value shows
1-digit, check that the Developing Assembly is installed,
and then perform remedy from "3".
1. Check installation of the Developing Assembly and the
Drum.
2. Clean the Patch Sensor Window.
3. Replace the Patch Sensor.
4. Replace the Drum.