Canon imageRUNNER ADVANCE C5255 Series Service Manual page 975

Hide thumbs Also See for imageRUNNER ADVANCE C5255 Series:
Table of Contents

Advertisement

COPIER > OPTION > FNC-SW
LOCLFIRM
Set to allow firmware update by file
Lv.1 Details
To set whether to permit the user (administrator) to update the
firmware from the remote UI using a local file.
This update is executed as a measure for vulnerability in emergency
situations.
Use case
When prohibiting the administrator to update the firmware using a file
Display/adj/set range
0 to1
0: Disabled, 1: Enabled
Default value
1
MC-FANSW
Setting of Controller Fan control
Lv.1 Details
To set full speed/half speed to fan control of the Controller Fan 1 and 2.
When "1: Full speed" is set, the heat exhaust efficiency is enhanced.
Use case
- When HDD damage occurs multiple times
- When the machine is installed in a high temperature environment in
which HDD damage is likely to occur
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: Half speed, 1: Full speed
Default value
0
BXNUPLOG
ON/OFF of Nup log at Inbox print
Lv.2 Details
To set whether to keep Nup log at Inbox print.
Use case
When keeping Nup log at Inbox print
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
0
SDLMTWRN
ON/OFF cpcty warn dspl at E-mail/I-Fax TX
Lv.1 Details
To set whether to display the warning message when sending data
that exceeds the upper limit value for the transmission data size via
E-mail/I-Fax.
Use case
For customization
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
0
JLK-PWSC
ON/OFF of PCAM password auth doc scan
Lv.2 Details
To set whether to scan the PCAM password authentication document
with the MEAP application.
Use case
When scanning the PCAM password authentication document
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
0
8
Service Mode > COPIER > OPTION > FNC-SW
8
Service Mode > COPIER > OPTION > FNC-SW
COPIER > OPTION > FNC-SW
FAX-INT
Set FAX RX print interruption oprtn mode
Lv.2 Details
To set the mode performing interruption operation of FAX reception
print automatically.
Use case
Upon user's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
- Do not set this item while charge management (charging by Coin
Manager, a device alone, etc.) is used.
- During an ongoing job for which delivery setting (offset, stapling, etc.)
is made, interruption operation is performed between sets.
Display/adj/set range
0 to 1
0: Normal, 1: Interruption operation mode
Default value
0
PDL-Z-LG
Setting of drawing algorithm
Lv.1 Details
To switch the drawing algorithm of the iR C series and the iR-ADV C
series to obtain output the user expects.
When 0 is set, image is output as displayed on the screen by the new
algorithm adopted from the iR-ADV C Series. Pseudo outline (boundary
for processing divided graphics separately) occurred with the iR C
series does not occur. However, when PDL job with special data
structure is sent, output the user expects may not be obtained.
When 1 is set, the drawing algorithm adopted by the conventional iR
C series is used. Output equivalent to that of the iR C Series can be
obtained; however, drawing-related phenomenon occurred with the
series occurs.
Use case
Upon user's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
Do not use setting value 2 and 3.
Display/adj/set range
0 to 3
0: Drawing algorithm of iR-ADV C series, 1: Drawing algorithm of the
conventional iR C series, 2, 3: For R&D use
Default value
0
CDS-LVUP
Set to allow CDS periodical update
Lv.1 Details
To set whether to allow the user (administrator) to use the periodical
update function linked with CDS.
When 1 is set, the periodical update function can be used from user
mode.
Use case
When allowing the user to use the periodical update function
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
Do not set 1 in Japan. The firmware cannot be updated by user.
Display/adj/set range
0 to1
0: Disabled, 1: Enabled
Default value
The value differs according to the location.
8-155
8-155

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents